3928 Lawnwood St
Fort Worth, Texas 76111-6539
Phone: 817.831.2626 Fax: 817.831.8258
www.solidiform.com
NDT
PURCHASE ORDER:085835
Service Date:
VENDOR
Central Texas Heat Treating & Testing, Inc.
5801 Denton Hwy
Ft.Worth , TX 76148-3758
ORDER DATE DATE REQUIRED
10/30/2024 11/13/2024
BUYER SHIPPING METHOD
SIMON COMPANY VAN
NDT
CERTIFICATIONS REQUIRED

All ink stamping applied by processor must not be on or immediately adjacent to any raised cast numbers unless specified by drawing.
LN QTY MATL SVC SPEC  REV OEM PART NUMBER/REV BP EO/ECN PL MPI WORK ORDER CTL # SOLN AGE PO: CUST/OEM
1 12 356 Etch BPS-4089  N BELLFW 206-040-533-001C/B F NA B ODS: - 11487/1 241402 29692 29695 4501648471 /
a) Chemical Milling (Etch) per: BPS-4089
2 12 356 PEN BPS-4089  N BELLFW 206-040-533-001C/B F NA B ODS: - 11487/1 241402 29692 29695 4501648471 /
    ZONE:
a) 100% Fluorescent Penetrant Inspection per: BPS-4089.
3 12 356 X-Ray BPS-4309  G BELLFW 206-040-533-001C/B F NA B ODS: - 11487/1 241402 29692 29695 4501648471 /
    CLASS: 2A    GRADE:
***********MAP part*********** a) Radiographic Inspect per: BPS-4309 b) Mark per BPS-4050 c) Vibro etch X-ray information per BP note 7C

Refer to BHTI secure web site (https://info.bhti.com/) for current Bell Specification Revisions.
WORK MUST BE IN ACCORDANCE WITH REQUIREMENTS POSTED ON OUR SUPPLIER WEB SITE: http://www.solidiform.com/supplier/